Products Current Location:Home > Products > Details
ANDO AQ6317 OSA
  • ANDO AQ6317 OSA
ANDO AQ6317 OSA
 

Product Model:

           AQ6317
 

Product Manufacturer:

           Ando
 

Product Attributes Classification:

           Optical Communication
 

Product Attributes:

           Optical Spectrum Analyzer
Product Description

AQ6317 Ando AQ6317 Optical Spectrum Analyzer

The AQ6317 is an advanced optical spectrum analyzer for a wide range of applications, including light source evaluation, measurement of loss wavelength characteristicsin optical devices, and waveform analysis of WDM (Wavelength Division Multiplexing) systems.Especially at 1550 nm band, the unit achieves high wavelength accuracy and wavelength linearity, and can evaluate optical devices for WDM. Analysis functions make operation and expandability simple.

 The AQ6317 contains the latest of Ando’s technology for optical spectrum analyzers. A reference equipment for the next generation.

Features:_ 50 GHz WDM-SignalsHigh-resolution measurement in a wide 50 GHz spectrum dynamic range._ Versatile analysis functionsAnalysis functions for WDM and other optical devices (LD, LED, FBG, etc.)_ High wavelength accuracy

Provides ±0.05 nm wavelength accuracy in the 1550 nm band, with ±0.01 nm wavelength linearity, making it especially useful for high-precision loss wavelength characteristic and other evaluation of WDM devices.The wavelength scale indicates both in air and in vacuum._ Synchronous sweepIn conjunction with a AQ4320 Tunable Laser Source, much higher wavelength resolution/wide dynamic range can be achieved by high-speed synchronous sweep._ High wavelength resolutionAchieves wavelength resolution of 0.015 nm_ High sensitivity over a wide band

Covers from 600 nm to 1750 nm and high sensitivity allow measurement of light at down to -90 dBm._ Low polarization dependancyMeasurements such as gain of optical amplifier can be proceeded accurately because polarization dependency is suppressed as low as ±0.05 dB._ High-level accuracyAccurate within a ±0.3 dB._ High power measurement: Max. +20 dBm (100 mW)Even high-power output from an optical amplifier can be measured directly without an optical attenuator._ 9.4-inch color LCD_ Pulsed light can be measured_ Three individual trace memories

 optical spectrum analyzer 

Previous:ANDO AQ6317B OSA
Next:ANDO AQ6317C OSA
About Us
Company Profile
Jobs
Operating Project
Company Culture
Products
Products
News
Industry News
Company News
Feedback
Feedback
Contact Us
Contact Us